Prolumia Catalog 2024

PROLUMIA W H E N L I G H T I N G M A T T E R S WWW.PROLUMIA.COM 206 207 100% 100% 100% 100% 100% 100% 0% / 100%, independent of daylight 0% / 100%, dependent on daylight A B 1 1 2 2 3 3 Off --> after motion detection 100% during delay time --> then off Off when there is enough ambient light --> in the evening/night after motion detection 100% during hold time --> then off 100% upon detection, during hold time. Off when there is sufficient daylight, also after detection. 100% upon detection, during hold time. 100% during hold time, in case of detection and insufficient daylight. Off after expiry of hold time. Off after expiry of hold time. Examples of sensor settings: MICROWAVE MOTION SENSOR PRO-AQUA III Detection range ceiling mounting: (at 100% sensitivity 3m mounting height and 0.3m/s speed) 8m Detection range wall mounting: (at 100% sensitivity 2m mounting height and 0.3m/s speed) 10m Maximum mounting height: 6m Sensitivity adjustment range: 25% - 50% - 75% - 100% Hold time: 5 - 30 - 90 sec.; 5 - 20 - 30 min. Daylight level: 2 - 10 - 30 - 50 lux - off PRO-AQUA III SERIES Specifications: PRO-AQUA III SERIES INDUSTRY PARKING MORE INFO ABOUT PRO-AQUA III ONLINE: MORE INFO ABOUT PRO-AQUA III ONLINE:

RkJQdWJsaXNoZXIy MTkzNjc=